this post was submitted on 29 Sep 2024
708 points (98.9% liked)

Lemmy Shitpost

27166 readers
3430 users here now

Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.

Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means:

-No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...

If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.


Also check out:

Partnered Communities:

1.Memes

2.Lemmy Review

3.Mildly Infuriating

4.Lemmy Be Wholesome

5.No Stupid Questions

6.You Should Know

7.Comedy Heaven

8.Credible Defense

9.Ten Forward

10.LinuxMemes (Linux themed memes)


Reach out to

All communities included on the sidebar are to be made in compliance with the instance rules. Striker

founded 2 years ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 12 points 2 months ago (1 children)

The only way that immediately springs to mind is so unlikely to happen. It requires multiple faults/mistakes.

1: The chassis of one of the two units became live (connected to "hot" for you Americans) but was also not grounded in any way.
2: The chassis of the other WAS grounded and created a circuit for the current to flow.
3: There was no RCD (GFCD or whatever you guys call it) on the circuit.

In this way, that pipe would be the only thing connecting the two devices, and the resistance is causing a huge amount of heat (just like an incandescent bulb, or a heating element does by design).

Probably other possibilities, but it's just the first thing I could think of that could potentially produce this result. But, that's a lot of safety features to have either failed or just simply not been in place for this to be possible. So, frankly I hope I'm totally wrong.

[–] [email protected] 2 points 2 months ago (1 children)

Even if that happened, wouldn't the pipe handle a lot more current than normal house wires, or even the main ones connecting the building to the grid. I assume the pipe would be thick enough that the wires in your walls would be glowing long before the pipe itself was.

[–] [email protected] 2 points 2 months ago

I would have thought so, but I think it depends on how thin the skin of the pipe is. I would also have expected a breaker to trip under that much load. But, based on that happening, I'd not be surprised if there are bypasses and/or broken breakers.

When we moved into the house we're in now, the RCD (GFCI) didn't work at all. I pressed test, nothing. Had the electrician over to change it. He tested the actual actuation using earth leakage. Nothing. So, faults can happen too.

I want to be wrong, though. Because that's a pretty bad state to get into, I think.