this post was submitted on 24 Aug 2024
953 points (99.3% liked)

Lemmy Shitpost

26915 readers
2687 users here now

Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.

Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means:

-No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...

If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.


Also check out:

Partnered Communities:

1.Memes

2.Lemmy Review

3.Mildly Infuriating

4.Lemmy Be Wholesome

5.No Stupid Questions

6.You Should Know

7.Comedy Heaven

8.Credible Defense

9.Ten Forward

10.LinuxMemes (Linux themed memes)


Reach out to

All communities included on the sidebar are to be made in compliance with the instance rules. Striker

founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] Pika 22 points 3 months ago* (last edited 3 months ago) (1 children)

The proper way of doing it is using what's called a generator bypass switch, basically it's a physical switch that runs before your fuse box, and it makes it impossible to have both the main and the generator being fed at the same time, so you can either have the main on or you could have the generator on. This prevents the electricity from your generator back feeding into the line and killing a line worker trying to restore power.

Sadly, like the other comments have said people tend to use these male to male cables in order to not have to pay the $2,000 to install the switch and instead choose to just turn the main breaker off and plug that cable in. But since it's possible to have both the main and the generator on it's not legal because if you forgot to throw the Main or if you did it incorrectly you could be putting workers at risk

Even disregarding the safety risk of using such a cable, not having a dedicated switch installed also means that you're plugging your generator into usually an outside socket of the house, and those power lines aren't usually meant to have a high load so you risk creating a fire from over straining the line as well

[–] [email protected] 3 points 3 months ago (1 children)

"risk a fire from staying the line with a high load", wouldn't the fuse in the line you plug it into simply open if you over load it?

[–] [email protected] 1 points 3 months ago

Well, if you put them right in the normal outlet you bypass breaker and built in fuses, if breaker is open. If it is closed, then it maybe should pop if whole net outside house consumes more current than your house is allowed to (so maybe immediately), but still provides no protection inside. Or maybe if you have individual low-current rated breakers for every outlet, then yes, in this specific scenario it should technically work. Still, you know, generally bad idea.