This was in a guesthouse bathroom, there was a showerhead pointed right at it.

top 22 comments
sorted by: hot top controversial new old
[–] Cheradenine 59 points 1 month ago (2 children)

This is a 20 amp circuit breaker, not only is it unprotected, when it failed someone bypassed it instead of replacing it with something correct. If you took a shower in the morning and water splashed on these open contacts you wouldn't need coffee to get your heart started.

[–] [email protected] 18 points 1 month ago (1 children)

Ignoring all the obvious bad decisions, what were they trying to accomplish? Even if that was wired correctly in a breaker panel enclosure I can't figure out why it would be placed in a location that had a shower head pointed at it.

[–] Cheradenine 9 points 1 month ago (1 children)

Honestly I thought about it and I'm not sure what the intention was. It could have been mounted on the other side of the wall (outside the bathroom) just as easily.

I'll have to dig it up but I have a photo of the old electric meter from the same place. It was buzzing quite loudly, then it melted. It would have been marginal when installed and was connected to only lights and ceiling fans, then they did a reno and added aircon and water heaters.

[–] [email protected] 7 points 1 month ago (1 children)

The meter melted? Jesus, that's a unique place isn't it haha

[–] Cheradenine 10 points 1 month ago (1 children)
[–] Trigger2_2000 2 points 1 month ago

Thanks for the pictures.

What country are those from (can't make out the markings on the meter)?

[–] [email protected] 3 points 1 month ago* (last edited 1 month ago) (1 children)

Is it a suicide shower (the kind where an unprotected 3000W+ heating wire runs through the water) with disconnected ground? (A grill around the nozzles is connected to a ground wire that is supposed to prevent the current from flowing into your body, but it tends to trip GFCI/RCD so stupid desperate people disconnect it against the advice in the manual. If they were desperate but smarter, they would connect the grill to neutral instead to prevent GFCI/RCD from tripping while maintaining slightly better leakage prevention.)

[–] Cheradenine 4 points 1 month ago

No it wasn't one of those, though I have gotten a surprise from them a few times.

This was a small wall mounted unit with a thermoblock heater. There was no ground of course.

[–] [email protected] 25 points 1 month ago (3 children)

I'm pretty sure there is an exception to that rule when it comes to electricity.

[–] Cheradenine 21 points 1 month ago (1 children)

The wood bullet into the tile grout was a nice touch I thought.

[–] [email protected] 8 points 1 month ago

Hey, it's supported!

...kinda

Fr tho this is some incredible jimbo work

[–] [email protected] 17 points 1 month ago (1 children)

It doesn't really even need an exception. Working means disconnecting when more than 20 A are drawn, and this doesn't do that. The rule works just fine, and counterexamples always boil down to someone misunderstanding the design goals and using a bad definition of works.

[–] Voroxpete 8 points 1 month ago (1 children)

Yeah, I'd argue that even taken more broadly any shower that kills the occupants cannot be said to "work" by any reasonable definition.

Obviously, we can all think of one very notable and very unreasonable definition, but I doubt that was the intention here.

[–] [email protected] 1 points 1 month ago

Yeah, I'd argue that even taken more broadly any shower that kills the occupants cannot be said to "work" by any reasonable definition.

Well, are they clean???

They were until they died and shit themselves.

Yes... That is a problem, then.

[–] [email protected] 0 points 1 month ago

it works fine (as a conductor), it just won't fail as one might expect (if they thought it had a fuse)/breaker)

[–] [email protected] 10 points 1 month ago

A fuckin jbox and outlet and plate will sum to about $15. Breakers cost more than that.

[–] [email protected] 9 points 1 month ago

I’d argue this is not an exception, just a misunderstanding of what “works” means. Clearly the “protecting wires in case of overload” function is not working…

[–] [email protected] 6 points 1 month ago (1 children)
[–] [email protected] 4 points 1 month ago

"We call it that cause if you take a shower and you touch it, ya dead!"

"Yes, that is accurate."

[–] [email protected] 5 points 1 month ago
[–] [email protected] 4 points 1 month ago (1 children)
[–] [email protected] 1 points 1 month ago

In which case, it's most likely one of the flow-heating suicide showers