393
LAN party from 2003 (files.catbox.moe)
submitted 1 month ago by [email protected] to c/[email protected]
top 50 comments
sorted by: hot top controversial new old
[-] [email protected] 112 points 1 month ago
[-] [email protected] 20 points 1 month ago

"...in you're LAN"

My second favorite Peter Gabriel song

[-] [email protected] 71 points 1 month ago

Can you imagine the power bill after running all those CRTs? Damn.

[-] [email protected] 29 points 1 month ago

Googling around it seems a 21" draws around 100W, which isn't as much as I thought; it's kinda a florescent light with more steps. A florescent backlit LCD doesn't use a whole lot less, and a modern 30-something inch LED backlit uses, as far as in an tell, about 1/3 that. So, for typical sized monitors, only ~70W more for CRT.

In contrast, the GPU wars mean that (I think?) power consumption in gaming desktops has gone up somewhat substantially


a 500W PSU was fairly beefy in 2003 (I think), whereas 1000W or more is pretty standard for a gaming computer now (obviously it's not drawing rated power, but assuming headroom % is roughly the same...).

My completely unsubstantiated guess would be that a LAN party setup as pictured would draw more power at idle, but a modern LAN party would draw more under load.

[-] [email protected] 13 points 1 month ago

I know enough about power systems to know that we're going to hit a hard limit on how much max power we're going to be able to plumb into a computer soon.

A single North American power circuit is approximately 120v and limited to 15A. The numbers wiggle a little from place to place, I've seen many that are running 115v or even closer to 110v. The 15A limit is not quite accurate either, since it's not recommended to load a circuit more than 80% for any continuous load, so your realistic maximum continual draw would be around 12A.

Some newer homes are being built with 20A, but most homes are still generally using 15A breakers.

At 120v, on a 15A circuit, you shouldn't consistently pull more than 12A, or 1440W. The line will max out at 1800W when the breaker/fuse will start to trigger.

So as power supplies hit 1200 to 1400 watts, you'll need to ensure that nothing else on the circuit will draw any significant power. A few displays and whatnot are fine, but with a 1200w PSU, you can't exceed 240w of additional draw while operating within the recommendations.

There are a few solutions to this, the obvious one is move to 20A, which can draw 1920W within the recommended power draw for the circuit, so you could have an 1800w system and about 120w of additional items before hitting the recommended limits, and 480w of total overhead before the breaker goes. The downside is that such circuits require thicker cables in-wall (12awg when 14awg is far more common in homes).

One option I'm aware of that nobody seems to consider is that in NA, the power delivered to the home is approximately 240v split-phase. 240v is generally only used for things like stovetops and ranges, electric dryers, water heaters, resistive heating in forced air furnaces, and air conditioning/heat pump systems. Though, it is entirely possible to convert a simple outlet to 240v. To be safe, you will need to get new receptacles, but you can reuse the wires already in the wall for 240v. I believe the NEMA 6-15R is the one that's rated for 240v operation in NA, and it's not dissimilar to the standard NEMA 5-15R that is the typical "North American" receptacle. However, a standard plug (aka a NEMA 5-15P) will not fit into the 240v receptacle. Any outlets on the same circuit would need to be changed so a 120v only device does not get plugged into the 240v receptacle. You can wire it for 240v at 15A which can provide up to 2880W of power without rewiring the house.

The trick will be to find a NEMA 6-15P to C13 connection for the PC and peripherals, and double checking that they will accept 240v power (all monitors and whatnot need to be set up to accept 240v power). On older power supplies, this is a simple switch on the outside of the PSU, though newer units will be switched, so they will detect the input power automatically.

I'm not recommending anyone does that, but if you do, talk to an electrician to ensure you're complying will all local ordinances.

Despite that, it is an option that most don't seem to consider.

Personally, I need to have some rewiring done in my residence and I'm going to see if I can get a dedicated 240v 20A single receptacle circuit installed for my computer, with the appropriate receptacles and everything.

To note: most 240v connections also have a neutral line (like what you would find with an oven or dryer), which the NEMA 6 receptacles do not have, they are 240v only. This, along with the fact that most 240v receptacles are rated for 30A+, makes them generally very large. The NEMA 6-15R and NEMA 6-20R are the 15/20A versions of 240v AFAIK, and they're not really any larger than a standard receptacle.

load more comments (7 replies)
[-] Kecessa 8 points 1 month ago

Oh yeah, modern PCs use a lot of power under load, I was renovating the main room in my condo in the middle of Canadian winter and was keeping the place warm by having two PCs mining crypto since I didn't have a baseboard!

[-] [email protected] 9 points 1 month ago

Key here is “under load.” When a computer is sitting idle nowadays it can use only tens of watts. My older computers often would burn 200w at all times just sitting there doing nothing.

[-] [email protected] 56 points 1 month ago

wonder what that smelled like

[-] [email protected] 53 points 1 month ago

exactly how it looks

[-] [email protected] 40 points 1 month ago

Like someone threw thermal paste and hormones on a barbecue

[-] [email protected] 13 points 1 month ago
load more comments (1 replies)
[-] [email protected] 12 points 1 month ago

I went to a well air conditioned one of these and surprisingly I don't remember it being a big deal. Looking how people are dressed here though.... probably rough.

[-] [email protected] 12 points 1 month ago

I remember the static of those CRT's having a particular smell too

[-] [email protected] 55 points 1 month ago

i can smell that room through my monitor, and 22 years later

[-] [email protected] 10 points 1 month ago
[-] [email protected] 31 points 1 month ago
[-] [email protected] 9 points 1 month ago

Lmao one of the first videos I ever saw on youtube, haven't seen that in 15 years probably and I heard it in my head instantly

[-] [email protected] 48 points 1 month ago

What's with all the shirtless people? We mostly kept our clothes on at our LAN parties.

[-] [email protected] 70 points 1 month ago

I can imagine it's just really hot in there with the computers and monitors going.

[-] [email protected] 13 points 1 month ago

I feel like aircon wasn't as common back then, especially strong enough to cool all of that

[-] [email protected] 22 points 1 month ago

It's more likely it wouldn't be able to handle the number of people + PCs. They are sized for use, and they may be hitting the limit with just the people in there, then add the BTUs coming off all that hardware, and you've got yourself a sauna.

[-] [email protected] 15 points 1 month ago

aircon wasn't as common back then

^ OP thinking 20-years ago was the 1960's. ;)

[-] [email protected] 5 points 1 month ago* (last edited 1 month ago)

Maybe it is an Australian thing?

In 2009 the school I went to got aircon

I have lived in very few houses that have had aircon, if they did it was evaporative and near useless. The house I am currently in is getting aircon installed next week.

It might be hot in Australia, but mainly we just built houses with insolation and fly screens.

[-] [email protected] 13 points 1 month ago

It would depend on the event hall. If it was in a warehouse like hall and in spring or fall, sure you'd keep your shirt on.

If it was in a event hall with a lower ceiling, carpet on the floor and just some form of insulation it'd get crazy hot really fast. Because on top of thousands of PC's there'd be thousands of people too. In summer it'd be even crazier. I definitely remember going shirtless at some of those lans.

load more comments (1 replies)
[-] [email protected] 41 points 1 month ago

all plugged into one janky power strip.

[-] [email protected] 32 points 1 month ago
[-] [email protected] 29 points 1 month ago

I think I was going to the wrong lan parties in the 90s because we all kept our shirts on, even when it was hot.

[-] [email protected] 9 points 1 month ago

Remember the smell at your parties? Imagine the smell here

(Not hating, I was there too, wouldn't trade it for the world, but I would be ok with a little febreeze and Old Spice)

load more comments (1 replies)
[-] [email protected] 27 points 1 month ago

You can tell this is AI because there are girls there

[-] [email protected] 22 points 1 month ago

I see we are also telling jokes from 2003.

[-] [email protected] 18 points 1 month ago

Let me tell you about chuck Norris...

load more comments (1 replies)
load more comments (4 replies)
[-] [email protected] 21 points 1 month ago

Just living in the moment, not a phone in sight.

[-] [email protected] 19 points 1 month ago
load more comments (1 replies)
[-] [email protected] 15 points 1 month ago

It looks like the same 4 or 5 people in different poses on repeat?

[-] [email protected] 9 points 1 month ago

Yup, the topless guy in the beige trousers is very noticeably everywhere.

load more comments (1 replies)
load more comments (1 replies)
[-] [email protected] 13 points 1 month ago* (last edited 1 month ago)

there are girls, this is fake

load more comments (1 replies)
[-] [email protected] 8 points 1 month ago

Is that Tom in front of the construction lights?

[-] [email protected] 8 points 1 month ago

I recognise almost all of those tower cases and had a couple myself.

load more comments (3 replies)
[-] [email protected] 5 points 1 month ago

Can we have this except with Steam Decks? How bad would we garble up the radio bands with all of them connecting to the Wi-Fi and various tethered phones?

[-] SomeAmateur 6 points 1 month ago

Bluetooth can have a few hundred unique connections

[-] [email protected] 6 points 1 month ago

And that's just when you start being able to taste your teeth!

[-] [email protected] 5 points 1 month ago

Acrid is the word

[-] [email protected] 5 points 1 month ago

Had MIDI parties in the 90s cuz we didn't have network cards yet. Just one big ring of machines all daisy chained together with MIDI cables. And it was awesome.

load more comments
view more: next ›
this post was submitted on 28 May 2024
393 points (97.3% liked)

Nostalgia

1252 readers
361 users here now

nostalgia noun nos·tal·gia nä-ˈstal-jə nə-, also nȯ-, nō-; nə-ˈstäl- 1: a wistful or excessively sentimental yearning for return to or of some past period or irrecoverable condition also : something that evokes nostalgia

Rules for Nostalgia Lemmy Community

1. Respectful Nostalgia Share nostalgic content and memories respectfully. Avoid offensive or insensitive references that may be hurtful to others.

2. Relevant Nostalgia Posts should focus on nostalgic content, including memories, media, and cultural references from the past. Stay on topic to preserve the nostalgic theme of the community.

3. Source Verification If you share nostalgic media or content, provide accurate sources or background information when possible.

4. No Spamming Avoid excessive posting of similar nostalgic topics to keep content diverse and engaging for all members.

5. Positive Discussions Encourage positive discussions and interactions related to nostalgic topics. Respect different viewpoints and memories shared by community members.

6. Quality Content Strive to post high-quality content that sparks nostalgia and meaningful conversations among members.

7. Moderation Guidelines

By adhering to these rules and guidelines, we can create a welcoming and enjoyable space to relive nostalgic moments together. If you have any questions or suggestions, feel free to reach out to the moderators. Thank you for sharing your nostalgia responsibly!

founded 1 year ago
MODERATORS