Hey!

Currently doing drywall myself and I am using 6x6 cm squared timber around my outside walls.

The problem is they aren't as stable as the other walls inside the house because of the 6x6 cm squared timbers that are about 30cm distance from each other.

I will screw my plasterboards on the squared timber and only one plasterboard, not two.

I have two pictures of what my construction looks like from far and one from close.

Maybe someone can give me advice before I install the plasterboard onto it.

The only problem I currently see is finding the subconstruction once I put the plasterboards back on. But other than that, if I find them can I install the cabinets safely?

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 8 points 9 months ago (2 children)
[–] [email protected] 12 points 9 months ago (2 children)

Are those studs not sitting on a plate?

[–] [email protected] 12 points 9 months ago* (last edited 9 months ago) (5 children)

Yeah there is so much crazy shit going on in these pictures I am doubting my own understanding and I was a rough carpenter for several years.

Why are the studs on the flat? Where the hell is that sill plate? No headers over the windows? No cripples under the windows? Is that stud next to the window opening cut at the bottom? Why are the studs spaced so… creatively

I could probably spot a few more but I honestly think I just don’t know what this building is or where it is. Clearly not in US and maybe it’s a shed or something and not a dwelling. Too much I don’t know to talk shit.

Edit: is there like an actual structural wall on the exterior that we cannot see? Maybe all this stuff is just to provide structure for drywall and electric. That would maybe make sense.

[–] [email protected] 12 points 9 months ago* (last edited 9 months ago)

From the links he sent, it looks like he’s just building a non-structural insulating wall on the interior which allows for running electrical lines.

[–] [email protected] 8 points 9 months ago* (last edited 9 months ago) (3 children)

Yeah, this isn't framing per his link. That OSB is the interior of the structural wall and he's just building out with 6x6 cm (what we'd think of as 2x2 inch) to hang his (likely 1/4" equivalent) drywall and provide electrical service.

https://www.wolfhaus.info/images/DETAILS/wandkonstruktion_oekoline.jpg

[–] [email protected] 9 points 9 months ago (2 children)

I think you’re right. If this picture was taken in the US or Canada, I would be panicked for OP. But honestly I thing it might be something we don’t do here so it looks crazy, but only to us.

[–] [email protected] 5 points 9 months ago

You're right. After moving to Germany, I can tell there is nothing wrong with this picture, but it sure looks crazy out of context.

Interestingly enough, most residential houses I looked at had solid, steel reinforced concrete walls everywhere.

[–] [email protected] 2 points 9 months ago

If this picture was taken in the US or Canada, I would be panicked for OP

Same tbh.

[–] [email protected] 3 points 9 months ago (1 children)

Oh, I see. Still not sure I’d hang cabinets from that.

[–] [email protected] 4 points 9 months ago (1 children)

I think it just depends on how he's attaching it. If it's going into the top and sill plates behind the OSB, there's not really much of a chance of it going anywhere.

[–] [email protected] 3 points 9 months ago (1 children)

But those gaps at the base, where the stud should be abutting a sill plate…what will the drywall be attached to?

[–] [email protected] 3 points 9 months ago* (last edited 9 months ago)

The sill plate is actually behind the OSB and looks thicker than anything we use. I don't honestly know if there's studs back there too, but I'd imagine so. I really don't know how that wall is constructed.

[–] [email protected] 1 points 9 months ago (1 children)

What does this mean? Am I doing something wrong?

[–] [email protected] 5 points 9 months ago* (last edited 9 months ago)

No, I was actually translating it for the American construction folks. What you're doing is actually how we cover up plaster walls on remodels. It's just not something I've ever dealt with when I was a construction supply salesperson.

[–] [email protected] 2 points 9 months ago

I worry they're just attaching things to the cladding.

[–] [email protected] 2 points 9 months ago (1 children)

I thought they were flat too, but he said they’re square. I’m very confused.

[–] [email protected] 3 points 9 months ago (1 children)

What do you mean? Sorry I am not english speaking.

[–] [email protected] 9 points 9 months ago (1 children)
[–] [email protected] 3 points 9 months ago (2 children)
[–] [email protected] 2 points 9 months ago

The wall is behind the 6x6 cm squared timber.

The reason for 6x6 cm squared timber is for the electricity level.

[–] [email protected] 1 points 9 months ago* (last edited 9 months ago)

This is translated, I don’t speak German.

Unter diesen 6 x 6 cm großen Stollen befindet sich kein Stück Holz. Es sieht so aus, als hätten sie keine nennenswerte strukturelle Unterstützung.