this post was submitted on 29 Jul 2024
306 points (98.7% liked)

World News

38506 readers
2796 users here now

A community for discussing events around the World

Rules:

We ask that the users report any comment or post that violate the rules, to use critical thinking when reading, posting or commenting. Users that post off-topic spam, advocate violence, have multiple comments or posts removed, weaponize reports or violate the code of conduct will be banned.

All posts and comments will be reviewed on a case-by-case basis. This means that some content that violates the rules may be allowed, while other content that does not violate the rules may be removed. The moderators retain the right to remove any content and ban users.


Lemmy World Partners

News [email protected]

Politics [email protected]

World Politics [email protected]


Recommendations

For Firefox users, there is media bias / propaganda / fact check plugin.

https://addons.mozilla.org/en-US/firefox/addon/media-bias-fact-check/

founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 12 points 1 month ago (10 children)

You just plug them into an outlet? Is there no safety concern about backfeeding power, especially if someone turns off the breaker and expects a circuit to be de-energized?

[–] [email protected] 32 points 1 month ago (8 children)

They're not supposed to be grid-forming and should turn off if there's no grid voltage. And if you turn off a breaker you should always check that there's no voltage, you might've turned off the wrong breaker.

[–] [email protected] 4 points 1 month ago (7 children)

That's good then. Although I hope they also considered what happens if there's two of them on a circuit, because if the mains power goes off, but there's another panel on the same circuit, they'd each see the other's voltage on the line, right?

And yeah, you should verify that a circuit is de-energized after you flip the breaker, but I've seen both some real weird electrical work, and some electricians who aren't that careful.

[–] [email protected] 11 points 1 month ago (1 children)

They generate no frequency so the situation you fear is not possible.

[–] [email protected] 5 points 1 month ago (1 children)

The panels themselves are DC, but there's an inverter feeding 120V 60Hz (or whatever) into the wall, right?

[–] [email protected] 16 points 1 month ago* (last edited 1 month ago) (2 children)

Yes, but it's a system that is designed to sync with the frequency of whatever other electricity is out there, and it shuts of if the main shuts off. Almost all rooftop systems without a battery in the US are set up the same way.

Still, it's important to check that things you think are disconnected do not have current flowing through them. And this makes it more important.

[–] [email protected] 1 points 1 month ago (1 children)

Pure sine wave or modified? Modified (square wave) are not good for electronics, particularly computers.

[–] [email protected] 1 points 1 month ago

The answer likely varies by model. Check.