this post was submitted on 24 May 2024
468 points (92.2% liked)

World News

39182 readers
1771 users here now

A community for discussing events around the World

Rules:

Similarly, if you see posts along these lines, do not engage. Report them, block them, and live a happier life than they do. We see too many slapfights that boil down to "Mom! He's bugging me!" and "I'm not touching you!" Going forward, slapfights will result in removed comments and temp bans to cool off.

We ask that the users report any comment or post that violate the rules, to use critical thinking when reading, posting or commenting. Users that post off-topic spam, advocate violence, have multiple comments or posts removed, weaponize reports or violate the code of conduct will be banned.

All posts and comments will be reviewed on a case-by-case basis. This means that some content that violates the rules may be allowed, while other content that does not violate the rules may be removed. The moderators retain the right to remove any content and ban users.


Lemmy World Partners

News [email protected]

Politics [email protected]

World Politics [email protected]


Recommendations

For Firefox users, there is media bias / propaganda / fact check plugin.

https://addons.mozilla.org/en-US/firefox/addon/media-bias-fact-check/

founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 1 points 6 months ago (1 children)

OK, I'm going to save you time because I do some controls and totally get how "easy" demand management should be given how simple most devices are.

But WHAT?! Thats all built into the grid over there??? That's AWESOME. Let me see if I have this right: there's essentially a small transient frequency modulation in the 60hz(?) in the grid that allows devices to receive a "off" signal?

I could be wrong but I'm 90% sure we've got nothing like that in the states. MAYBE there's something like that for communicating with the meter itself but certainly not past the meter.

[–] [email protected] 1 points 6 months ago

I think you might have it in the US but not for residential customers.

No, frequency-modulating the 50/60 Hz is not technically feasible, that would mean speeding up/slowing down lots of synchronous motors quickly. Instead, a higher-frequency low-voltage generator is connected in series or in parallel (via a capacitor) to the secondary of a grid transformer, overlaying some 3V sine wave at 216⅔ Hz (or other frequency thereabouts) on top of the 230V 50Hz mains. This does not propagate beyond 50 km or so (and higher frequencies (red on map) even worse) so multiple transmitters are required for coverage. The country's grid is divided into districts and each gets their own RCS signal, and signal traps (low pass or band stop fiters) are used to divide them.