Cca != CCA
The Cca standard relates to the flammability and toxicity of the materials used to jacket the cable. You can read about it here: https://cabling.crxconec.com/en/crx-blog/CRX-Blog-02.html
CCA stands for Copper Clad Aluminum. The actual conductors (each wire) is made from aluminum that has been given a thin coating of copper. This is what you want to avoid since it can be less durable and likely to have more voltage drop for PoE. It's unrelated to the Cca standard.
So assuming you are running this wire for a fixed installation, you should be looking for Cca + solid copper (not stranded). The one you linked to looks good.
Get shielding if it will be run near strong interference sources, and only if the shielding will be grounded.