This is a community for individuals who are interested in running their own IT infrastructure at home. Personally, I have a server rack (like you might see in a datacenter) with a few servers installed in it. I use it for streaming video and audio to my TVs and portable devices, bulk storage, load-sharing two internet connections, monitoring security cameras, writing code, and a whole lot of other things.
"NUT" stands for "Network UPS Tools" and is a program that connects to an UPS (battery backup) and provides monitoring and remote shutdown based on power status. Unfortunately, as you say, I am having problems with my NUT at the moment.
Any sort of messages in syslog or dmesg?
When it gets in the problem state, does the UPS respond when you use upsc to check its status in a terminal in the vm?
If so it might be taking too long to respond when it is being checked by the daemon. If so setting MAXAGE to something higher than the 15s default may help. A lot of people raise it to 25 for this symptom. But this will only help if the driver is still connecting to the UPS ok. If it's not then it may be a problem with the USB connection or the UPS.